Air-to-wa­ter heat pump NIBE LI

The NIBE LI series is ideal for environmentally sound, energy-efficient, and convenient heating. It fits in any basement and is perfect for new builds and renovations.

Application
Single-family house, multi-family house, especially for renovation (but also new construction)
Installation
Indoor installation
Operating range
9.00 - 24.3 kW

Pro­duct de­tails

The advantages of NIBE LI at a glance:

  • Large projects – high capacity
    The perfect solution for modernization and larger projects
  • Ideal for every home
    Operating ranges from 9.00 to 24.3 kW
  • Suitable capacity in the transition period
    Good partial load coverage thanks to 2-stage operation
  • High efficiency
    With a COP of up to 4.4
  • Operating range for every climate
    Supply temperature up to 60°C
  • Overview and status
    Full control and monitoring even from a distance thanks to the Internet connection

Cli­ma­te pre­mi­um

Are you replacing a fossil gas or oil heating system with a renewable heating system? Benefit from attractive subsidies.

References

  • LI | Öffentlichkeit | Schegge di legno | Umgebungsluft | UTSD

    Mul­ti-pur­po­se fa­ci­li­ty, 9103 Schwell­brunn

Do you have any ques­ti­ons?

Benefit from our many years of experience and let our specialists advise you individually, without obligation and free of charge.

Fre­quent­ly as­ked ques­ti­ons?

The heat pump extracts thermal energy from the ambient air. The refrigerant absorbs this heat in the heat exchanger (evaporator) and is then compressed in the compressor. The heat generated in this process is used for heating and hot water production via another heat exchanger. In summer, the cycle can also be used for cooling by reversing the process.

The heat pump extracts thermal energy from the ground using a geothermal probe or groundwater. The refrigerant absorbs this heat in the heat exchanger (evaporator) and is then compressed in the compressor. The heat generated in this process is used for heating and hot water production via another heat exchanger. In summer, the cycle can also be used for cooling by reversing the process.

Heat pumps are suitable for both and can therefore be used in new buildings and old buildings undergoing renovation. With the latest generation of heat pumps, flow temperatures of up to 70° can be achieved.
However, it may be worth replacing or adding new radiators with a larger heating surface area in order to increase the efficiency of the heat pump. Seek advice from a specialist. In general, energy-saving measures should be considered for the building envelope in order to directly reduce the heat demand and thus reduce the flow temperatures and increase the efficiency of the heat pump.

Yes, because all our heat pump systems are designed for the design temperature. However, there are some differences between the various heat pump systems that need to be taken into account:

Air/water heat pumps:
Air/water heat pumps have a lower operating limit (approx. -25°C). For heating systems, this means that the heat output is guaranteed up to the design temperature (in the Swiss Plateau, for example, at -7°C). If the outside temperature falls below this design temperature, the auxiliary heating can switch on automatically. Statistically speaking, however, this is extremely rare.

Brine/water heat pumps:
With brine/water heat pumps, it is important to dimension the geothermal probes correctly. The geothermal energy at depth is constant and changes only minimally, even if the top layer of soil is frozen.

A heat pump with a COP of 5 requires 1/5 of the total energy produced in the form of electrical energy, while 4/5 of the energy is obtained from the environment (ambient air, geothermal probe, etc.).
The COP is highly dependent on the source temperature and the flow temperature. The higher the source temperature and the lower the flow temperature, the higher the COP and the energy efficiency.
In combination with a PV system, the amount of electricity consumed can be increased and energy costs reduced.

The sound insulation of heat pumps can be improved through structural measures. The most important measure is to physically decouple the heat pump from the house. Pipes must also be physically decoupled using suitable mounting systems. Sound insulation hoods or sound insulation walls can also significantly reduce noise levels.

Heat pumps are generally very low-maintenance. However, a heat pump should not be neglected. Contamination on the outdoor unit or in the heating circuit, incorrect settings, incorrect heating curves, etc. can damage the heat pump or reduce its efficiency. Periodic maintenance is therefore always beneficial and extends the service life.

LI 2-STAGE air/water heat pump, indoor installation

The LI series is perfect for environmentally sound, energy-efficient, and convenient heating. What’s more, the flexible air/water heat pump fits in any basement. Suitable for new builds and renovations. Cascade option for high capacity with low installation costs.

With the indoor version, there is no need to install a heat pump outside. So if you don’t like the look of a system visible in your garden, you can opt for this version. If the boundary distance is an issue, you can gain a few important meters here.
  • Large projects – high capacity
    Perfect solution for modernization and larger projects
  • Optimal for every home
    Operating ranges from 9.00 to 24.3 kW
  • Suitable capacity in the transition period
    Good partial load coverage thanks to 2-stage operation
  • High efficiency
    With a COP of up to 4.4
  • Operating range for every climate
    Supply temperature up to 60 °C